What is the difference between Probe/Mini-Loop/Magnetometer, Entry Pulse, Exit Pulse Functions?
This article explains the differences between difference between Probe/Mini-Loop/Magnetometer, Entry Pulse, Exit Pulse Function.
Entry Pulse - The B output will be activated for 250 ms when the loop becomes occupied while A output is on presence as soon as loop is occupied all the way until becomes vacant.
Exit Pulse - The B output will be activated for 250 ms when the loop becomes vacant while A output is on presence as soon as loop is occupied all the way until becomes vacant.
Probe function - Outputs A and B will be activated for 250 ms when the loop becomes occupied.
Probe, Mini-Loop and Magnetometer, Free Exit Probe are the same thing.